资源描述:
raising standards worldwide™ NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BSI British Standards Cable trunking systems and cable ducting systems for electrical installations Part 2-4 Particular requirements for service poles and service posts BS EN 50085-2-42009 National foreword This British Standard is the UK implementation of EN 50085-2-42009. The UK participation in its preparation was entrusted to Technical Committee PEL/213, Cable management. A list of organizations represented on this committee can be obtained on request to its secretary. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. BSI 2009 ISBN 978 0 580 59270 6 ICS 29.120.10 Compliance with a British Standard cannot confer immunity from legal obligations. This British Standard was published under the authority of the Standards Policy and Strategy Committee on 31 August 2009 Amendments issued since publication Amd. No. Date Text affected BRITISH STANDARDBS EN 50085-2-42009 EUROPEAN STANDARD EN 50085-2-4 NORME EUROPENNE EUROPISCHE NORM June 2009 CENELEC European Committee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat Avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any and by any means reserved worldwide for CENELEC members. Ref. No. EN 50085-2-42009 E ICS 29.120.10 English version Cable trunking systems and cable ducting systems for electrical installations - Part 2-4 Particular requirements for service poles and service posts Systmes de goulottes et systmes de conduits-profils pour installations lectriques - Partie 2-4 Rgles particulires pour les colonnes et colonnettes Elektroinstallationskanalsysteme fr elektrische Installationen - Teil 2-4 Besondere Anforderungen fr freistehende Installationseinheiten This European Standard was approved by CENELEC on 2009-05-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions English, French, German. A version in any other language made by translation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 50085-2-42009 EN 50085-2-42009 – 2 – Foreword This European Standard was prepared by the Technical Committee CENELEC TC 213, Cable management systems. The text of the draft was ted to the al vote and was approved by CENELEC as EN 50085-2-4 on 2009-05-01. The following dates were fixed – latest date by which the EN has to be implemented at national level by publication of an identical national standard or by endorsement dop 2010-05-01 – latest date by which the national standards conflicting with the EN have to be withdrawn dow 2012-05-01 This European Standard is a system standard for cable management products used for electro- technical purposes. It relates to Low Voltage Directive 2006/95/EC 1 through consideration of the essential requirements of this directive. This European Standard is supported by separate standards to which references are made. This Part 2-4 is to be used in conjunction with EN 50085-12005 “Cable trunking systems and cable ducting systems for electrical installations – Part 1 General requirements”. This Part 2-4 supplements or modifies the corresponding clauses of EN 50085-12005. Where a particular clause or subclause of Part 1 is not mentioned in this Part 2-4, that clause or subclause of Part 1 applies as far as is reasonable. Where this Part 2-4 states “addition” or “replacement”, the relevant text of Part 1 is to be adapted accordingly. NOTE The following numbering system is used – subclauses, tables and figures that are additional to those in Part 1 are numbered starting from 101; – additional anns are lettered AA, BB, etc. __________ 1 Directive 2006/95/EC of the European Parliament and of the Council of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits, OJ L 374, 27.12.2006, p. 10–19. BS EN 50085-2-42009 – 3 – EN 50085-2-42009 Contents Page 1 Scope ............................................................................................................................... 4 2 Normative references........................................................................................................ 4 3 Definitions ........................................................................................................................ 5 4 General requirements ....................................................................................................... 5 5 General conditions for tests .............................................................................................. 5 6 Classification .................................................................................................................... 6 7 Marking and documentation .............................................................................................. 7 8 Dimensions ....................................................................................................................... 7 9 Construction ..................................................................................................................... 7 10 Mechanical properties ....................................................................................................... 8 11 Electrical properties ........................................................................................................ 15 12 Thermal properties ......................................................................................................... 16 13 Fire hazard ..................................................................................................................... 16 14 External influences ......................................................................................................... 16 15 Electromagnetic compatibility .......................................................................................... 17 Annex A inative Types of cable trunking systems CTS and cable ducting systems CDS ...................................................................................................................... 22 Annex B inative A-deviations ....................................................................................... 22 Annex C normative CTS/CDS IK code ................................................................................ 22 Annex AA normative Use of test results according to EN 50085-2-4 for service poles and service posts being part of a CTS/CDS intended for wall or ceiling mounting covered by EN 50085-2-1 or floor mounting covered by EN 50085-2-2 ................................... 23 Annex AB normative Routine test for the socket outlets wiring of pre-wired service poles and service posts correct polarity and protection against electric shock ...................... 26 Figures Figure 101 − Types and application of service poles and service posts .................................. 19 Figure 102 – Detail of the cylinder for vertical load test in accordance with 10.5.103 .............. 20 Figure 103 – Detail of the circular plate for vertical load test in accordance with 10.5.104 ...... 21 Tables Table AA.1 – EN 50085-2-1 ................................................................................................... 23 Table AA.2 – EN 50085-2-2 ................................................................................................... 24 Table AB.1 – Diagrammatic representation of routine tests to be applied to the socket outlets wiring of pre-wired service poles and service posts .................................................... 26 BS EN 50085-2-42009 EN 50085-2-42009 – 4 – 1 Scope Replacement This European Standard specifies requirements and tests for cable trunking systems CTS and cable ducting systems CDS intended for the accommodation, and where necessary for the electrically protective separation, of insulated conductors, cables and possibly other electrical equipment in electrical and/or communication systems installations. The maximum voltage of these installations is 1 000 V a.c. and 1 500 V d.c. Service poles and service posts are intended to be mounted in free space and in contact with mounting surfaces only at one or two ends, where the word “mounted” means fixed or placed on the floor with a weighted base or linked to a mounting surface through a flexible component. NOTE Service poles and service posts can also be part of a CTS/CDS intended for wall or ceiling mounting covered by Part 2-1 or floor mounting covered by Part 2-2 and are then also tested according to Part 2-1 and/or Part 2-2 as appropriate. This European Standard does not apply to conduit systems, cable tray systems, cable ladder systems, powertrack systems or equipment covered by other standards. This European Standard shall be used in conjunction with EN 50085-12005 “Cable trunking systems and cable ducting systems for electrical installations – Part 1 General requirements” which is referred to in this document as Part 1. 2 Normative references This clause of Part 1 is applicable except as follows Add the following references EN 20535 1994 Paper and board – Determination of water absorptiveness – Cobb ISO 5351991 EN 50085-1 2005 Cable trunking systems and cable ducting systems for electrical installations – Part 1 General requirements EN 60068-2-75 1997 Environmental testing – Part 2-75 Tests – Test Eh Hammer tests IEC 60068-2-751997 EN 60695-11-2 2003 Fire hazard testing – Part 11-2 Test flames – 1 kW nominal pre-mixed flame – Apparatus, confirmatory test arrangement and guidance IEC 60695-11-22003 EN 62262 2002 Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts IK code IEC 622622002 EN ISO 536 1996 Paper and board – Determination of grammage ISO 5361995 ISO 9328-7 2004 Steel flat products for pressure purposes – Technical delivery conditions – Part 7 Stainless steels BS EN 50085-2-42009 – 5 – EN 50085-2-42009 3 Definitions This clause of Part 1 is applicable except as follows Additional definitions 3.101 service pole CTS/CDS intended to be mounted in free space and in contact with mounting surfaces only at two ends NOTE 1 Service pole can be part of a CTS/CDS intended for wall, ceiling or floor mounting. NOTE 2 The word “mounted” means fixed or placed on the floor with a weighted base or linked to a mounting surface through a flexible component. 3.102 service post CTS/CDS intended to be mounted in free space and in contact with mounting surface only at one end NOTE 1 Service post can be part of a CTS/CDS intended for wall, ceiling or floor mounting. NOTE 2 The word “mounted” means fixed or placed on the floor with a weighted base or linked to a mounting surface through a flexible component. 3.103 pre-equipped service pole / service post service pole / service post already assembled by the manufacturer or responsible vendor with one or more electrical accessories and/or communication components 3.104 pre-wired service pole / service post service pole / service post already assembled by the manufacturer or responsible vendor, wired by means of insulated conductors and/or cables connecting one or more electrical accessories and/or communication components 3.105 modular service pole / service post service pole / service post which includes the assembly of two or more modules allowing to increase the height or width or depth of the product 3.106 rated current, rated voltage value assigned to a pre-wired and/or pre-equipped service pole / service post by the manufacturer and to which operation and perances characteristics are referred 4 General requirements This clause of Part 1 is applicable. 5 General conditions for tests This clause of Part 1 is applicable except as follows 5.1 Replace by 5.1 Unless otherwise specified, tests according to this standard are type tests. BS EN 50085-2-42009 EN 50085-2-42009 – 6 – Additional subclause 5.101 Unless otherwise specified in the relevant test, service poles / service posts are tested on the longest version declared by the manufacturer and service poles / service posts which differ only by being shorter than one which complies with the requirements for a given test are deemed to comply with the requirements for the same test. 6 Classification This clause of Part 1 is applicable except as follows 6.4.1 This subclause of Part 1 is not applicable. Additional subclauses 6.101 According to floor treatment for service poles / service posts placed on the floor 6.101.1 Service poles / service posts for dry-treatment of floor 6.101.2 Service poles / service posts for wet-treatment of floor 6.102 According to resistance to vertical load applied through small surface area 6.102.1 CTS/CDS for 500 N 6.102.2 CTS/CDS for 750 N 6.102.3 CTS/CDS for 1 000 N 6.102.4 CTS/CDS for 1 500 N 6.102.5 CTS/CDS for 2 000 N 6.102.6 CTS/CDS for 2 500 N 6.102.7 CTS/CDS for 3 000 N 6.103 Optional classification according to resistance to vertical load applied through large surface area 6.103.1 CTS/CDS for 2 000 N 6.103.2 CTS/CDS for 3 000 N 6.103.3 CTS/CDS for 5 000 N 6.103.4 CTS/CDS for 10 000 N 6.103.5 CTS/CDS for 15 000 N BS EN 50085-2-42009 – 7 – EN 50085-2-42009 7 Marking and documentation This clause of Part 1 is applicable except as follows 7.3 Add the following three last indents - for modular service poles / service posts the constraints concerning the number or configuration of assembled modules; - whether non vertical mounting is allowed; - whether the flexible component, if any, linking to the mounting surface is not part of the enclosure. 8 Dimensio
展开阅读全文